Cellulose is the denser blown-in. New cellulose is about R-3.6 per inch. We use it when the ceiling can take the weight. The shop is 4263 NW 1st Ave, Boca Raton, FL 33431. Call (561) 654-7698.

Cardinal Insulation, 4263 NW 1st Ave, Boca Raton, FL 33431. Blown-in insulation is the first service. Cellulose is one of the two products. Fiberglass is the other. They are not the same R-value, and a quote that prints one band for both is hiding the choice.

The number

New cellulose is about R-3.6 per inch. Cellulose already in the attic is counted at about R-3.2. From a bare ceiling, R-38 is about 10.5 inches. Over four inches of settled fiberglass, about R-9, the gap is about 8 inches of new cellulose. Fiberglass for that same gap is about 12 inches, because new fiberglass is about R-2.5 per inch and settled fiberglass is about R-2.2.

A cellulose bag covers fewer square-foot-inches than a fiberglass bag, about 220 against about 640, because the fiber is packed denser. Bag count is the second check on the depth. It is not a number we invent after the truck is empty.

When we use it

We blow cellulose when the ceiling can carry it and the attic is a match: a sound drywall lid, a span that is not already complaining, and no reason to keep the layer as light as fiberglass. We do not switch to cellulose because the R-per-inch looks better on a proposal. An old plaster ceiling, a long span, or a lid that already holds a thick layer stays with the lighter product.

Dry cellulose that is already there gets counted and topped. Wet cellulose, or cellulose full of nests, comes out first. That removal is its own price. Cellulose does not air-seal the ceiling. The holes are closed before the hose, the same as fiberglass. The install page is blown-in insulation. The Boca neighborhoods are on blown-in insulation in Boca Raton.

Florida's zone 1 ceiling minimum is R-30. We install R-38 and check the inches. Cellulose is not R-49, and it is not a reason to close the soffit vents.

Measured against the Florida code

The attic numbers, not a brochure

The 2023 Florida Building Code, Energy Conservation, Table R402.1.2 sets a climate zone 1 ceiling at R-30 and a climate zone 2 ceiling at R-38. Cardinal installs R-38 and checks the inches. A Florida page that lists R-49 to R-60, or R-3.2 to R-3.8 per inch for both fiberglass and cellulose, is using a different book. Table R402.4.1.1 says air-permeable insulation shall not be used as the air seal.

Quotes are prepared by Russell Y, a building scientist, BPI certified, and certified to perform blower door testing. When the door is run, the result is air changes per hour at 50 pascals, the method in R402.4.1.2. That section limits new houses in climate zones 1 and 2 to 7 ACH50. An insulation job on an existing house is not automatically that test. We report the number only when we measured it.

Insulation numbers Cardinal uses against the Florida code
ItemNumberWhat it means
Zone 1 ceiling, Florida codeR-30 minimumPalm Beach and Broward
Zone 2 ceiling, Florida codeR-38 minimumNot R-49 and not R-60
What Cardinal installsR-38, depth checkedAbove the zone 1 floor
New blown fiberglassAbout R-2.5 per inchNot R-3.2 to R-3.8
Settled fiberglassAbout R-2.2 per inch4 inches is about R-9
New celluloseAbout R-3.6 per inchDenser. Still not an air seal
Open-cell foamAbout R-3.6 per inchA roof-deck product
Closed-cell foamAbout R-6.5 per inch2 inches is about R-13

Loose fill does not stop air. The holes are sealed first. Two inches of closed-cell foam is an air-seal coat, not a finished attic. We do not quote a dollar amount off the power bill. Ducts in a vented attic stay in the heat. The shop for the Boca listing is 4263 NW 1st Ave.

Blown-in insulation, the full pageResidential insulationWhich insulation belongs in a Florida houseWho writes the quoteHow a South Florida attic actually works