CardinalInsulation

Service pages

Keyword map

Each search a homeowner types, the page that answers it, and which shop that page is allowed to name. The Boca listing is 4263 NW 1st Ave, Boca Raton, FL 33431. Call (561) 654-7698. Blown-in insulation is the first service. Radiant barrier, duct sealing, and crawl-space encapsulation are not on this map.

SearchPageListing
Insulation contractor in Boca Raton/Boca shop
Insulation contractors near me/Boca shop
Blown-in insulation/blown-in-insulationBoca shop
Blown-in insulation Boca Raton/blown-in-insulation-boca-ratonBoca shop
Blown-in insulation Delray Beach/delray-beachDelray shop
Blown-in insulation Boynton Beach/boynton-beachDelray shop, no Boynton pin
Attic insulation Boca Raton/attic-insulationBoca shop
Spray foam insulation Boca Raton/spray-foamBoca shop
Air sealing Boca Raton/air-sealingBoca shop
Cellulose insulation Boca Raton/cellulose-insulationBoca shop
Fiberglass insulation/blown-in-insulationBoca shop
Batt insulation Boca Raton/batt-insulationBoca shop
Residential insulation/residential-insulationBoca shop
Which insulation for a Florida house/which-insulationBoca shop
Insulation removal/insulation-removalBoca shop. Page is written for Delray Beach.
Attic sanitizing/attic-sanitizingBoca shop. Page is written for Delray Beach.
Rodent proofing/rodent-proofingBoca shop
Commercial blown-in insulation/commercial-blown-inBoca shop
Commercial attic insulation/commercial-attic-insulationBoca shop
Commercial batt insulation/commercial-batt-insulationBoca shop
Commercial spray foam/commercial-spray-foamBoca shop
Metal building spray foam/metal-building-spray-foamBoca shop

Measured against the Florida code

The attic numbers, not a brochure

The 2023 Florida Building Code, Energy Conservation, Table R402.1.2 sets a climate zone 1 ceiling at R-30 and a climate zone 2 ceiling at R-38. Cardinal installs R-38 and checks the inches. A Florida page that lists R-49 to R-60, or R-3.2 to R-3.8 per inch for both fiberglass and cellulose, is using a different book. Table R402.4.1.1 says air-permeable insulation shall not be used as the air seal.

Quotes are prepared by Russell Y, a building scientist, BPI certified, and certified to perform blower door testing. When the door is run, the result is air changes per hour at 50 pascals, the method in R402.4.1.2. That section limits new houses in climate zones 1 and 2 to 7 ACH50. An insulation job on an existing house is not automatically that test. We report the number only when we measured it.

Insulation numbers Cardinal uses against the Florida code
ItemNumberWhat it means
Zone 1 ceiling, Florida codeR-30 minimumPalm Beach and Broward
Zone 2 ceiling, Florida codeR-38 minimumNot R-49 and not R-60
What Cardinal installsR-38, depth checkedAbove the zone 1 floor
New blown fiberglassAbout R-2.5 per inchNot R-3.2 to R-3.8
Settled fiberglassAbout R-2.2 per inch4 inches is about R-9
New celluloseAbout R-3.6 per inchDenser. Still not an air seal
Open-cell foamAbout R-3.6 per inchA roof-deck product
Closed-cell foamAbout R-6.5 per inch2 inches is about R-13

Loose fill does not stop air. The holes are sealed first. Two inches of closed-cell foam is an air-seal coat, not a finished attic. We do not quote a dollar amount off the power bill. Ducts in a vented attic stay in the heat. The shop for the Boca listing is 4263 NW 1st Ave.

Blown-in insulation, the full pageResidential insulationWhich insulation belongs in a Florida houseWho writes the quoteHow a South Florida attic actually works