An insulation contractor in Jupiter installs and removes insulation. Blown-in insulation is the first service. The code floor here is R-30. The install on a vented attic is R-38. Call (561) 654-7698.

The Jupiter shop. 17628 Brian Way, Jupiter, FL 33478

The shop is 17628 Brian Way, Jupiter, FL 33478. The phone is (561) 654-7698. Blown-in insulation is loose fill on a vented attic floor, after the holes are sealed. Spray foam is the roof deck, and only when the vents over that roof are closed. The contractor is not the roofer and not the pest company.

Jupiter is three attics. Abacoa and the streets off Indiantown Road are production tile roofs. The inlet side in 33477 is tighter and older, and the hatch often has to be rebuilt before anyone can stand. Jupiter Farms in 33478 is acreage: long truss runs, and a barn on the same lot as the house.

The city page is blown-in insulation in Jupiter. The job, with the inches and the bags, is blown-in insulation. What an insulation contractor is hired to do, without a city, is the contractor page.

Request a Jupiter quote

Measured against the Florida code

The attic numbers, not a brochure

The 2023 Florida Building Code, Energy Conservation, Table R402.1.2 sets a climate zone 1 ceiling at R-30 and a climate zone 2 ceiling at R-38. Cardinal installs R-38 and checks the inches. A Florida page that lists R-49 to R-60, or R-3.2 to R-3.8 per inch for both fiberglass and cellulose, is using a different book. Table R402.4.1.1 says air-permeable insulation shall not be used as the air seal.

Quotes are prepared by Russell Y, a building scientist, BPI certified, and certified to perform blower door testing. When the door is run, the result is air changes per hour at 50 pascals, the method in R402.4.1.2. That section limits new houses in climate zones 1 and 2 to 7 ACH50. An insulation job on an existing house is not automatically that test. We report the number only when we measured it.

Insulation numbers Cardinal uses against the Florida code
ItemNumberWhat it means
Zone 1 ceiling, Florida codeR-30 minimumPalm Beach and Broward
Zone 2 ceiling, Florida codeR-38 minimumNot R-49 and not R-60
What Cardinal installsR-38, depth checkedAbove the zone 1 floor
New blown fiberglassAbout R-2.5 per inchNot R-3.2 to R-3.8
Settled fiberglassAbout R-2.2 per inch4 inches is about R-9
New celluloseAbout R-3.6 per inchDenser. Still not an air seal
Open-cell foamAbout R-3.6 per inchA roof-deck product
Closed-cell foamAbout R-6.5 per inch2 inches is about R-13

The attics on this page

Jupiter is three attics. Abacoa and the streets off Indiantown Road are production tile roofs. The inlet side in 33477 is tighter and older, and the hatch often has to be rebuilt before anyone can stand. Jupiter Farms in 33478 is acreage: long truss runs, and a barn on the same lot as the house.

A dry Abacoa attic is an air seal and a top-up to R-38. Farms is the same product and a longer day because the attic is bigger and the hose run is longer. The barn is not the house. Say which building is hot.

The shop is Cardinal Insulation of Jupiter, 17628 Brian Way, Jupiter, FL 33478. The phone is (754) 253-9607. Blown-in insulation is the first service. Tequesta is 33469, the next city north, not a Jupiter ZIP.

The code in Jupiter

Jupiter is in Palm Beach County. Table R301.1 of the 2023 Florida Building Code, Energy Conservation, lists Palm Beach County as climate zone 1A. Table R402.1.2 sets the zone 1 ceiling minimum at R-30. Jupiter does not publish its own attic R-value. The city enforces the Florida Building Code.

Palm Beach County is not in the High-Velocity Hurricane Zone. That zone is only Miami-Dade and Broward. Parts of the Palm Beach coast are still a wind-borne debris region, which is an opening-protection rule from the wind map, not an insulation number. Section R806.2 of the 2023 Florida Building Code, Residential, sets the net free vent area at 1/150 of the attic. The exception is 1/300 only when 40 to 50 percent of that area is within 3 feet of the ridge and the rest is in the bottom third. Insulation cannot close the soffit. R806.3 requires at least 1 inch at the eave vent.

The county zone is Table R301.1. The Boca Raton worked example, including the vent math, is the building code page. Cardinal still installs a vented attic to R-38 and checks the depth.

Blown-in insulation, the full pageResidential insulationWhich insulation belongs in a Florida houseWho writes the quoteHow a South Florida attic actually works