Insulation contractor in Pembroke Pines

An insulation contractor in Pembroke Pines installs and removes insulation. Blown-in insulation is the first service. The code floor here is R-30. The install on a vented attic is R-38. Call (561) 654-7698.

Map of the Pompano Beach shop. There is no Pembroke Pines pin. 681 SW 16th Ter, Pompano Beach, FL 33069

There is no insulation contractor shop in Pembroke Pines. The crew comes from the Pompano Beach shop at 681 SW 16th Ter, Pompano Beach, FL 33069. The phone is (561) 654-7698. Blown-in insulation is loose fill on a vented attic floor, after the holes are sealed. Spray foam is the roof deck, and only when the vents over that roof are closed. The contractor is not the roofer and not the pest company.

Pembroke Pines is a long city. 33024 and 33025, toward Hollywood and University Drive, are the older houses. Towngate is on this side. 33026 is the middle, around Flamingo Road, including Grand Palms. A golf villa with a flat roof and no attic is not the house next door.

The city page is blown-in insulation in Pembroke Pines. The job, with the inches and the bags, is blown-in insulation. What an insulation contractor is hired to do, without a city, is the contractor page.

Request a Pembroke Pines quote

Measured against the Florida code

The attic numbers, not a brochure

The 2023 Florida Building Code, Energy Conservation, Table R402.1.2 sets a climate zone 1 ceiling at R-30 and a climate zone 2 ceiling at R-38. Cardinal installs R-38 and checks the inches. A Florida page that lists R-49 to R-60, or R-3.2 to R-3.8 per inch for both fiberglass and cellulose, is using a different book. Table R402.4.1.1 says air-permeable insulation shall not be used as the air seal.

Quotes are prepared by Russell Y, a building scientist, BPI certified, and certified to perform blower door testing. When the door is run, the result is air changes per hour at 50 pascals, the method in R402.4.1.2. That section limits new houses in climate zones 1 and 2 to 7 ACH50. An insulation job on an existing house is not automatically that test. We report the number only when we measured it.

Insulation numbers Cardinal uses against the Florida code
ItemNumberWhat it means
Zone 1 ceiling, Florida codeR-30 minimumPalm Beach and Broward
Zone 2 ceiling, Florida codeR-38 minimumNot R-49 and not R-60
What Cardinal installsR-38, depth checkedAbove the zone 1 floor
New blown fiberglassAbout R-2.5 per inchNot R-3.2 to R-3.8
Settled fiberglassAbout R-2.2 per inch4 inches is about R-9
New celluloseAbout R-3.6 per inchDenser. Still not an air seal
Open-cell foamAbout R-3.6 per inchA roof-deck product
Closed-cell foamAbout R-6.5 per inch2 inches is about R-13

The attics on this page

Pembroke Pines is a long city. 33024 and 33025, toward Hollywood and University Drive, are the older houses. Towngate is on this side. 33026 is the middle, around Flamingo Road, including Grand Palms. A golf villa with a flat roof and no attic is not the house next door.

33028 and 33029 are west of I-75. Chapel Trail and Pembroke Falls are newer, wider, and often sitting at the R-30 code floor rather than R-38. The edges, over the tray ceiling and the garage, are where the original install stopped.

There is no Pembroke Pines pin. The Broward shop is in Pompano Beach. The Boca shop is in Boca Raton. Distance is the limit on a near-me search from west of I-75. The page is the attic and the ZIP, not a second listing.

The code in Pembroke Pines

Pembroke Pines is in Broward County. Table R301.1 lists Broward as climate zone 1A. The zone 1 ceiling minimum is R-30. Pembroke Pines does not publish a separate insulation number.

Broward County is in the High-Velocity Hurricane Zone, with Miami-Dade. The whole county is in it, not just the beach. Chapter 44 of the 2023 Florida Building Code, Residential, sends roof assemblies, wall coverings, and windows to the stricter Building-code chapters. Roofing and openings used there need approval for HVHZ use, a Miami-Dade or Broward Notice of Acceptance or a Florida Product Approval that includes the HVHZ. That is a roof and window rule. It does not change the attic ceiling from R-30, and a blown-in job does not carry a roof product approval. Section R806.2 of the 2023 Florida Building Code, Residential, sets the net free vent area at 1/150 of the attic. The exception is 1/300 only when 40 to 50 percent of that area is within 3 feet of the ridge and the rest is in the bottom third. Insulation cannot close the soffit. R806.3 requires at least 1 inch at the eave vent.

The county zone is Table R301.1. The Boca Raton worked example, including the vent math, is the building code page. Cardinal still installs a vented attic to R-38 and checks the depth.

Blown-in insulation, the full pageResidential insulationWhich insulation belongs in a Florida houseWho writes the quoteHow a South Florida attic actually works