CardinalInsulation

Hollywood, Florida

Insulation contractor in Hollywood

An insulation contractor in Hollywood installs and removes insulation. Blown-in insulation is the first service. The code floor here is R-30. The install on a vented attic is R-38. Call (561) 654-7698.

Map of the Pompano Beach shop. There is no Hollywood pin. 681 SW 16th Ter, Pompano Beach, FL 33069

There is no insulation contractor shop in Hollywood. The crew comes from the Pompano Beach shop at 681 SW 16th Ter, Pompano Beach, FL 33069. The phone is (561) 654-7698. Blown-in insulation is loose fill on a vented attic floor, after the holes are sealed. Spray foam is the roof deck, and only when the vents over that roof are closed. The contractor is not the roofer and not the pest company.

East of I-95, 33019 and 33020, the beach, Young Circle, Liberia, and Hollywood Lakes are older block houses and short attics. A flat roof with no cavity is not a blown-in job. A stack of condos with no scuttle is not either.

The city page is blown-in insulation in Hollywood. The job, with the inches and the bags, is blown-in insulation. What an insulation contractor is hired to do, without a city, is the contractor page.

Request a Hollywood quote

Measured against the Florida code

The attic numbers, not a brochure

The 2023 Florida Building Code, Energy Conservation, Table R402.1.2 sets a climate zone 1 ceiling at R-30 and a climate zone 2 ceiling at R-38. Cardinal installs R-38 and checks the inches. A Florida page that lists R-49 to R-60, or R-3.2 to R-3.8 per inch for both fiberglass and cellulose, is using a different book. Table R402.4.1.1 says air-permeable insulation shall not be used as the air seal.

Quotes are prepared by Russell Y, a building scientist, BPI certified, and certified to perform blower door testing. When the door is run, the result is air changes per hour at 50 pascals, the method in R402.4.1.2. That section limits new houses in climate zones 1 and 2 to 7 ACH50. An insulation job on an existing house is not automatically that test. We report the number only when we measured it.

Insulation numbers Cardinal uses against the Florida code
ItemNumberWhat it means
Zone 1 ceiling, Florida codeR-30 minimumPalm Beach and Broward
Zone 2 ceiling, Florida codeR-38 minimumNot R-49 and not R-60
What Cardinal installsR-38, depth checkedAbove the zone 1 floor
New blown fiberglassAbout R-2.5 per inchNot R-3.2 to R-3.8
Settled fiberglassAbout R-2.2 per inch4 inches is about R-9
New celluloseAbout R-3.6 per inchDenser. Still not an air seal
Open-cell foamAbout R-3.6 per inchA roof-deck product
Closed-cell foamAbout R-6.5 per inch2 inches is about R-13

The attics on this page

East of I-95, 33019 and 33020, the beach, Young Circle, Liberia, and Hollywood Lakes are older block houses and short attics. A flat roof with no cavity is not a blown-in job. A stack of condos with no scuttle is not either.

33021 is Hollywood Hills and Emerald Hills, west of I-95. Those are the wider ranch attics, original batts, and a longer walk from the hatch to the eave. 33023 and 33024 run into Pembroke Pines. The tax bill decides the city.

There is no Hollywood pin. The Broward shop is 681 SW 16th Ter, Pompano Beach, FL 33069. The Boca shop is 4263 NW 1st Ave. A near-me search in Hollywood starts closer to shops that are already standing there. This page names the attics. It does not move either pin south.

The code in Hollywood

Hollywood is in Broward County. Table R301.1 lists Broward as climate zone 1A. The zone 1 ceiling minimum is R-30. Hollywood does not publish a separate insulation number.

Broward County is in the High-Velocity Hurricane Zone, with Miami-Dade. The whole county is in it, not just the beach. Chapter 44 of the 2023 Florida Building Code, Residential, sends roof assemblies, wall coverings, and windows to the stricter Building-code chapters. Roofing and openings used there need approval for HVHZ use, a Miami-Dade or Broward Notice of Acceptance or a Florida Product Approval that includes the HVHZ. That is a roof and window rule. It does not change the attic ceiling from R-30, and a blown-in job does not carry a roof product approval. Section R806.2 of the 2023 Florida Building Code, Residential, sets the net free vent area at 1/150 of the attic. The exception is 1/300 only when 40 to 50 percent of that area is within 3 feet of the ridge and the rest is in the bottom third. Insulation cannot close the soffit. R806.3 requires at least 1 inch at the eave vent.

The county zone is Table R301.1. The Boca Raton worked example, including the vent math, is the building code page. Cardinal still installs a vented attic to R-38 and checks the depth.

Blown-in insulation, the full pageResidential insulationWhich insulation belongs in a Florida houseWho writes the quoteHow a South Florida attic actually works